Pre- and post-analytical automation

Gain full control over your pre-analytical tasks with documented process control – standardized but flexible.

We offer dedicated platforms designed to fulfill IVD Directive 98/79/EC, with 21 CFR Part 11-compliant software, as well as open liquid handling platforms configured according to your needs.

For automation of tedious, error-prone pre-analytical tasks, Tecan offers the Fluent Mix and Pierce Workstation which eliminates the need to decap and recap tubes for pipetting and provides consistent sample mixing for standardized results.




***************************************************************************************
***************************************************************************************
Tab 01 / Overview
***************************************************************************************
***************************************************************************************




***************************************************************************************
***************************************************************************************
Tab 02 / Pre-Analytics
***************************************************************************************
***************************************************************************************




***************************************************************************************
***************************************************************************************
Tab 03 / Post-Analytics
***************************************************************************************
***************************************************************************************

Automated sample archiving and retrieval

Laboratories need to be able to accommodate requests for retrospective analysis or reflex testing.

Enjoy efficient archiving with the smallest member of the Freedom EVO® family, for fast sample transfer from primary tubes to 2D barcoded cryo tubes.

The Freedom EVO 100 system allows safe and accurate collection of clinical samples, as well as easy access and retrieval when further testing is required.

Small space – 96 samples per run – high convenience.

  • Automated aliquoting of laboratory-defined volumes of human plasma samples from 1D barcoded primary tubes to 2D barcoded cryotubes for archiving
Show more
  • The aliquot volume can be easily adapted according to the needs of the laboratory
  • Image-based, user-guided set-up
  • Sample retrieval with scan and search function
  • Disposable tips to eliminate cross-contamination
  • A choice of two-channel pipetting for fast return of investment or a four-channel pipetting option delivering higher throughput in the same small amount of lab space
  • Host connectivity

Freedom EVO configuration

  • PosID™ 1D barcode scanner for primary tube, rack and carrier identification
  • Flat 2D barcode scanner for identification of cryotubes
  • Two- or four-channel Liquid Handling Arm™ for transferring samples from primary to destination tubes
  • Manual barcode scanner for sample retrieval

Load and go sample transfer

Full traceability. The instrument matches the 1D barcodes of the primary tubes with the 2D barcoded secondary tubes and creates a worklist without the need to configure a host connection.

Host connectivity. The archiving information can be transferred to the LIS.

Clot identification. The system’s Freedom EVOware® software identifies clotted samples. If a clot is detected, the instrument pauses, notifies the user, and then proceeds according to the instructions given.

Standardization. Automation of sample aliquoting and archiving protocols increases throughput, frees up staff time, and removes the potential for human error that is inherent in tedious, time-consuming manual pipetting processes.

Operator safety. Primary tube racks can be loaded directly onto the workdeck, minimizing contact with potentially infectious samples. The workdeck is protected by a transparent front panel with electromagnetic locks controlled by the software. The system is completely closed, with an optional exhaust hood.

Simple aliquot identification. An external handheld barcode scanner is incorporated for straightforward scanning and identification of cryotube racks.

The information contained in the archive file record includes

  • Cryotube rack barcode
  • Sample barcode
  • Aliquot barcode
  • Position of the aliquot in the cryotube rack
  • Date and time of aliquot creation
  • Aliquot volume
  • Original primary sample volume

Efficient separation of plasma or serum from the cellular layer

The user can define the transfer volume of serum or plasma for each run. Protocols for the separation of different sample volumes can be pre-programmed and selected by the user before the run start.




***************************************************************************************
***************************************************************************************
Tab 04 / Software
***************************************************************************************
***************************************************************************************




***************************************************************************************
***************************************************************************************
Tab 05 / Literature
***************************************************************************************
***************************************************************************************